Homeowners Professionals
Vitocal 300-G Pro
Vitocal 300-G Pro

Large heat pump

Ground source heat pump with the option of water/water operation with intermediate brine circuit.

Rated heating output: 84.9 to 222.2 kW
Use of groundwater with an intermediate circuit
Space efficient design
For commercial enterprises and local authority premises
Rated heating output for brine/water operation

84.9 to 222.2 kW

Rated heating output for water/water operation

107.2 to 283.0 kW

Space efficient design

Entrance to the installation location needs to be just 850 mm wide

Use of groundwater with an intermediate circuit

Water/water application with an intermediate brine circuit

Pre-assembled electrical equipment

Enables quick installation

Proven technology

Ensures reliable functionality

Ground source heat pump

Single and two-stage

Low running costs thanks to high coefficients of performance

COP (coefficient of performance) to EN 14511: up to 4.6 (B0/W35) and 5.8 (W10/W35)

Maximum flow temperature

60 °C (brine 5 °C) for all sizes

Low noise and low vibrations

Due to sound-optimised appliance design

Maximum efficiency at every operating point

Through innovative refrigerant cycle diagnostic system with electronic expansion valve

Easy to use Vitotronic control unit

With plain text and graphic display

Ready to use connection

For fail-safe primary and secondary pumps

Electronic soft starter system

For reduced starting current and less power drawn from the mains

Total sound power level

Between 57 and 69 dB(A) at rated heating output (B0/W35)

Control Series

Vitotronic 200 WO1C

Vitocal 300-G Pro large ground source heat pump
With five output sizes, the Vitocal 300-G Pro large ground source heat pump reliably meets most requirements in residential and commercial properties.

Vitocal 300-G Pro – ground source heat pumps for large residential and commercial buildings

The Vitocal 300-G Pro heat pumps with up to 222.2 kilowatts are manufactured in series. The Pro series features all the characteristics of the highly efficient Vitocal 300‑G series. With five output sizes, most requirements from residential and commercial buildings can be reliably met. These appliances are standardised, enabling quick and comprehensive system design, as well as transparent cost calculation parameters. Higher output levels can be achieved by linking up to five Vitocal 300-G Pro in a cascade.

The hermetically sealed design with new scroll technology requires little space. At only 850 millimetres wide, with removable casing panels and a clearance at the bottom to enable transportation by pallet truck, the appliance is very easy to manoeuvre.

The water/water application with an intermediate brine circuit provides a reliable solution for the direct use of groundwater. An intermediate exchanger protects the standard unit against contamination and reduces the maintenance work for the heat pump.

The electrical equipment is already integrated inside the heat pump casing. Factory-fitted contactors for fail-safe primary and secondary pumps, as well as protection for the compressors, reduce installation effort and ensure rapid heat pump installation.

The control philosophy has been adopted from the Vitocal series for detached and two-family houses. Here too, the refrigerant cycle diagnostic (RCD) system checks efficiency continuously and ensures reliable function at every operating point through interaction with the electronic expansion valve (EEV) and the extensive sensor technology.

Easy to operate Vitotronic control unit with plain text and graphic display

The Vitotronic 200 regulates up to three heating circuits and, thanks to its natural cooling function, ensures a pleasant indoor environment on hot summer days. An extensive range of monitoring and system optimisation settings can be adjusted from anywhere, via the internet or a smartphone, utilising the Vitocom 300 communication module that is available as an option.

 

Vitotronic 200 control unit
Vitotronic 200 control unit

Combination with air/brine heat exchanger

In conjunction with an air/brine heat exchanger, the Vitocal 300-G Pro offers both cooling operation and the use of air as a heat source. The air/brine heat exchanger is connected to the heat pump via a brine circuit and enables heat recovery at an air temperature of down to -5 °C. Below -5 °C, a second heat generator takes over the heat supply in dual alternative mode. This allows for flexible system design and the formation of a robust system together with a second heat generator.

For such air/water applications, both the Vitocal 300-G Pro and the air/brine heat exchanger designed for this purpose are available. An attractive solution from a single source.

Product details

Rated heating output (kW), to EN 14511, B0/W35, spread 5 K

Type BW 302.D090 & BWR/BWS 302.DS090: 84.9 kW | type BW 302.D110 & BWR/BWS 302.DS110: 108.7 kW | type BW 302.D140 & BWR/BWS 302.DS140: 135.3 kW | type BW 302.D180 & BWR/BWS 302.DS180: 174.9 kW | type BW 302.D230 & BWR/BWS 302.DS230: 222.2 kW

Rated heating output (kW), to EN 14511, W10/W35, spread 5 K

Type BW 302.D090 & BWR/BWS 302.DS090: 107.2 kW | type BW 302.D110 & BWR/BWS 302.DS110: 139.8 kW | type BW 302.D140 & BWR/BWS 302.DS140: 175.0 kW | type BW 302.D180 & BWR/BWS 302.DS180: 227.0 kW | type BW 302.D230 & BWR/BWS 302.DS230: 283.0 kW

Coefficient of performance ε (COP) B0/W35

Type BW 302.D090 & BWR/BWS 302.DS090: 4.55 | type BW 302.D110 & BWR/BWS 302.DS110: 4.49 | type BW 302.D140 & BWR/BWS 302.DS140: 4.35 | type BW 302.D180 & BWR/BWS 302.DS180: 4.49 | type BW 302.D230 & BWR/BWS 302.DS230: 4.60

Coefficient of performance ε (COP) W10/W35

Type BW 302.D090 & BWR/BWS 302.DS090: 5.74 | type BW 302.D110 & BWR/BWS 302.DS110: 5.78 | type BW 302.D140 & BWR/BWS 302.DS140: 5.74 | type BW 302.D180 & BWR/BWS 302.DS180: 5.84 | type BW 302.D230 & BWR/BWS 302.DS230: 5.64

Application area

Residential buildings, commercial enterprises, local authority premises, modernisation projects, new build

Operation

Vitotronic 200 control unit with plain text and graphic display